5% EXTRA DISCOUNT on offers - COD: CYBER5QMUK - Until 8/12! | CYBER WEEK - SEE PRODUCTS

7% EXTRA DISCOUNT on QM products in stock! | COD: 7INSTOCKUK SEE PRODUCTS

Electrocautery for monopolar and bipolar surgery

General product safety

Manufacturer Information:

Name or company: Pending update
Email: Pending update
Postal address: Pending update
City: Pending update
Country: Pending update

Responsible person information:

Name or company: Pending update
Email: Pending update
Postal address: Pending update
City: Pending update
Country: Pending update

Warnings and product safety information:

Open document

Manufacturer Information:

Name or company: Pending update
Email: Pending update
Postal address: Pending update
City: Pending update
Country: Pending update

Responsible person information:

Name or company: Pending update
Email: Pending update
Postal address: Pending update
City: Pending update
Country: Pending update

Warnings and product safety information:

Open document

Manufacturer Information:

Name or company: Pending update
Email: Pending update
Postal address: Pending update
City: Pending update
Country: Pending update

Responsible person information:

Name or company: Pending update
Email: Pending update
Postal address: Pending update
City: Pending update
Country: Pending update

Warnings and product safety information:

Open document

Pay securely with:
Item reference188-QUI10100201
Item reference188-QUI10100301
Item reference188-QUI10100101
Electric radiofrequency scalpel for microcoagulation interventions and for small and medium surgery, monopolar or bipolar. Applications: ambulatory, pediatric, dermatology, first aid, otorhinolaryngology, urology ...
Description
  • Radiofrequency electrocautery, ideal for micro coagulation interventions and for small and medium surgery, either monopolar or bipolar.
  • Pure cuts, cuts with coagulation and bipolar coagulation can be performed using a special adapter.
  • Thanks to the digital readout of the power supplied, the applications of this instrument are safe and highly reproducible.
  • Allows highly professional surgery thanks to its ergonomic and safe design.
  • The connection to the neutral reference electrode offers constant monitoring.
  • The possibility of switching functions and control the power output through the electrode holder handpiece allow to carry out the surgery without having to concentrate on anything but the operative field.

Use in bipolar mode:

To use the machine in bipolar mode, the following items must be purchased:

  • Adapter for bipolar function (Ref. 138-00498-00)
  • Silicone cable for bipolar electrocautery (Ref. 138-CB463E)

  • Bipolar electrodes or forceps (see optional accessories)

Applications:

Description

Q80

188-QUI10100101

Q120

188-QUI10100201

Q160

188-QUI10100301

Medical consultation surgery  Recommended Recommended Recommended
Pediatric surgery Not recommended Not recommended Suitable
Plastic surgery  Not recommended Not recommended Suitable
Vascular surgery Suitable Recommended Recommended
Dental Recommended Suitable Not recommended
Dermatology Recommended Recommended Recommended
Endoscopy Not recommended Not recommended Suitable
Gynecology Not recommended Suitable Recommended
Gastroenterology Not recommended Not recommended Suitable
Neurosurgery Not recommended Not recommended Suitable
Orthopedics Not recommended Not recommended Suitable
Otolaryngology Not recommended Suitable Recommended
Pneumology Not recommended Not recommended Suitable
Emergency Suitable Recommended Recommended
Urology Not recommended Not recommended Suitable
Veterinary Suitable Recommended Recommended

Controls:

  • Control circuit/patient OC board.
  • Control of the radiated power.
  • Self diagnosis.

Technical features:

  • Working frequency: 600 kHz
  • Neutral electrodes: F
  • Voltage: 115 -230 VAC
  • Line frequency: 50-60 Hz
  • Unit weight: 5 Kg
  • Unit dimensions: 104 x 254 x 288 mm  
  80 120 160
Maximum power cutting CUT 80 W 120 W 160 W
Maximum power cutting / coagulation BLEND 60 W 90 W 120 W
Maximum power coagulation COAG FORCED 50 W 80 W 100 W
Maximum power coagulation SOFT COAG 40 W 60 W 80 W
Maximum power bipolar coagulation BIPOLAR COAG 30 W 40 W 60 W
Maximum power consumption 230 VA 300 VA 350 VA

INCLUDED ACCESSORIES:
 

  • Power cable
  • Footswitch
  • Cable for patient plate (ref. 138-00404.08)
  • Kit autoclavable electrodes (10 pcs)
  • Reusable metal patient plate (ref. 138-5365A)
  • Reusable handle with buttons


CERTIFICATION:

  • EC Directive 93/42 Medical Devices.


OPTIONAL ACCESSORIES:

  • 138-00500.00: Kit 10 assorted electrodes 5 cm (L1, L2, L3, L4, L5, L6, L7, L8, L9 and L10)
  • 138-152-112: Reusable curved blade electrode length 7 cm model D01
  • 138-152-115: Reusable blade electrode length 16 cm model E02
  • 138-152-122: 7 cm curved needle electrode model D04
  • 138-152-125: Reusable needle electrode length 13 cm model E01
  • 138-152-130: Ø 2 mm 6 cm sphere electrode model D05
  • 138-152-132: Round curved electrode Ø 2 mm 6 cm model D06
  • 138-152-140: Ø 3 mm 6 cm sphere electrode model D07
  • 138-152-145: Round electrode Ø 3 mm 14 cm model E03
  • 138-152-165: Round electrode Ø 5 mm 14 cm model E04
  • 138-152-190-13: Handle electrode 20x13 L. 15 cm model E05
  • 138-152-175-10: Handle electrode 10x10 L.15 cm model E06
  • 138-152-190-20: Handle electrode 20x20 L. 15 cm model E07
  • 138-152-195: 13 cm conization electrode model E08
  • 138-190-260: M4-MP4 3mt monopolar cable
  • 138-310-110-05: Bipolar forceps 11.5 cm TIP0.5mm
  • 138-310-112-05: Curved bipolar clamp 11.5 cm TIP0.5mm
  • 138-500500.L1: Slim and straight electrode cable 5 cm long (5 pcs)
     

Reviews
({{ review }})

REAL REVIEWS FROM OUR CUSTOMERS ABOUT QUIRUMED

Copyright 2004-2024 | Quirumed S.L.U. | CIF: B97267405 | Registered in the Mercantile Reg. Of Valencia. Volume 7319, Book 4620, Section 8, Folio 91, Page V-86377 | RII-AEE: 5331