Standard vital signs monitor
Manufacturer Information:
Name or company: Pending update
Email: Pending update
Postal address: Pending update
City: Pending update
Country: Pending update
Responsible person information:
Name or company: Pending update
Email: Pending update
Postal address: Pending update
City: Pending update
Country: Pending update
Warnings and product safety information:
Manufacturer Information:
Name or company: Pending update
Email: Pending update
Postal address: Pending update
City: Pending update
Country: Pending update
Responsible person information:
Name or company: Pending update
Email: Pending update
Postal address: Pending update
City: Pending update
Country: Pending update
Warnings and product safety information:
Vital signs monitor with a functional design and great maneuverability thanks to its handle, its discrete buttons board and its lightness. Its TFT LCD touchscreen of bright colours provide an excellent visibility.
STANDARD CONFIGURATION:
- SpO2, PR, NIBP, ECG, RESP, TEMP
- Colour touch TFT display
- Convenient for adults, and for paediatric and neonate patients
- Adjustable sound and visual alarms
ECG
- Lead selection:
- 3 derivations: RA, LA, LL (I, II, III)
- 5 leads: RA, LA, LL, RL, V (I, II, III, aVR, aVL, aVF, V)
- Heart rate range: 15 – 300 bpm
- Precision: ±1% or ±1 bpm
- Resolution: 1 bpm
- Pacemaker pulse inhibition:
- Amplitude: ±2 mV - ±700 mV
- Width: 0.1 ms – 2 ms
- Rise time: 10 us – 10 µs
- Sensitivity: > 200 uV
- Input impedance: > 5 µ ohm
RESP
- Range: 0 - 120 rpm
- Precision: ±2 rpm
- Resolution: 1 rpm
- Asphyxia alarm: 10 – 40 s
- Base impedance range: 200 – 400 ohm
- Impedance measuring range: 0.3 – 3ohm
- Bandwidth: 0.1 – 2.5 Hz
NIBP
- Method of measurement: oscillometry
- Operational mode: manual, automatic, STAT
- Measurement range of the automatic mode: 1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240, 480 minute(s)
- Measurement time of the STAT mode: 5 m
- Heart rate range: 40 – 240 rpm
- Systolic blood pressure range: 40 – 270 mmHg
- Diastolic blood pressure range: 10 – 215 mmHg
- Average pressure range: 20 – 235 mmHg
- Static pressure range: 0 – 300 mmHg
- Static pressure precision: ±3 mmHg
SPO2
- Range: 0 – 100%
- Resolution: 1%
- Precision:
- 70 – 100% : ±2 %
- 0 – 69%
- Pulse frequency range: 20 to 300 bpm
- Pulse frequency resolution: 1 bpm
- Pulse frequency precision: 3 bpm
TEMP
- Channel: 2
- Range: 0 – 50 ºC
- Resolution: 0.1ºC
- Precision: ± 0ºC plus the tolerance of the temperature sensor
WITH:
- Vital signs monitor
- Temperature probe
- Oximetry sensor
- ECG cable
- Cuff for adults
- Built-in battery
- User manual
- Power cord