Sku: 922-STE-B8D

8-liter class B autoclave with USB and double safety lock

8-liter Class B autoclave for laboratories, research centers, tattoo studios, and aesthetic clinics. Designed with a double lock for greater safety during the process. Reaches maximum temperatures of up to 134°C.
-3%
€1,677 99
RRP: €1,723.99
Excluding VAT: €1,364.22
Shipping costs Ship to:

Description

8 liter class B autoclave with USB and double safety lock.

Programs:

  • Solid
  • Wrapped
  • Textile
  • Prion
  • B&D Test
  • Helix Test
  • Vacuum test

Security:

  • A cycle will not start unless the door is properly closed.
  • Automated system with double hydraulic safety locking device, prevents the door from opening while the chamber is pressurized.
  • Safety valves prevent overpressure in the generator and chamber.
  • A safety thermostat prevents overheating in the chamber and the generator.
  • An automatic safety lock prevents accidental opening of the door during the sterilization process. An electrical protector automatically cuts off the power if there is a short circuit anywhere or the power supplier is not very stable.
  • Failure alarm, indicates a cycle failure and details the error code.
  • Door alarm indicates that the door is not secured.
  • Low water alarm, indicates when the water tank is empty or too full.

Technical specifications:

  • Nominal voltage: 220-240 VAC; 50/60 Hz; 10A
  • Camera dimensions: 170 x 320 mm
  • Circuit breaker: F16A / 400V
  • Nominal Power: 1500 VA
  • 1500W
  • Sterilization temperature: 121 ºC / 134 ºC
  • Distilled water tank capacity: 2.5 L
  • Operating temperature: 5ºC / 40ºC
  • Operating relative humidity: Max. 80%, non-condensing
  • External dimensions: 414 x 365 x 530 mm
  • Net weight: 37 Kg
  • Maximum noise level: <70 dB
  • Atmospheric operating pressure: 76 kPa / 106 kPa
  • Languages: Spanish, English, German, French, Portuguese, Italian, Dutch, Polish, Romanian, Czech, Latvian, Lithuanian, Hungarian and Chinese.

Components:

  • Distilled water tank
  • LCD screen
  • control Panel
  • Main switch
  • Tap for draining distilled and used water
  • USB port
  • Safety valve
  • Ventilation grille
  • Locking system
  • Power cable
  • Label

Included accessories:

  • Sterilizer
  • USB
  • 2 Instrument Trays
  • Tray support
  • Handle for removing the trays
  • Door adjustment tool
  • 2 Drain hoses
  • Door seal
  • Instruction manual

Regulations:

  • 93/42/EEC Medical Health Directive.
  • 97/23/EEC Pressure Equipment Directive.
  • EN 13060 Small water steam sterilizers.
  • EN 61326, EN 61000 Electromagnetic compatibility.
  • EN 61010-1, UL 61010-1 Safety requirements.
  • EN 61010-2-040, IEC 61010-2-040 Specific requirements for steam sterilizers used for the treatment of medical materials.

AUTOCLAVE PROCESS STEP BY STEP

  1. Open the door, take the instruments and accessories inside the sterilization chamber, remove the wrapping and proceed to clean them.
  2. Connect the power cord to a suitable power source.
  3. Connect the printer (optional. Sold separately, ref. 922-PRINTER04 ).
  4. Power On: The main power switch is located on the lower right front of the unit. Once activated, the LCD screen will illuminate, displaying the sterilizer's basic operating icons, such as door position, water level, sterilization program, date, time, etc.
  5. Fill the tank with distilled water. Remove the top cap of the tank and begin filling it. If you hear a signal, it means you have exceeded the permitted water level in the tank. Please stop immediately and drain the necessary amount of water until the signal turns off.
  6. Preparation of the material to be sterilized:
    1. Place instruments made of different materials in separate trays, but be sure to separate them before sterilization.
    2. If the instruments are not made of stainless steel, place sterilizing paper between the tray and the instruments.
    3. Do not allow direct contact between instruments made of different materials.
    4. Verify that all instruments are in the correct position.
    5. Place instruments such as lenses, containers, tubes, etc. in the tray upside down, so that water does not stagnate inside them.
    6. Do not overload the trays beyond their limit.
    7. Do not stack the trays on top of each other, nor place them in direct contact with the wall of the sterilization chamber.
    8. Do not use metal clips or pins, this may jeopardize the functioning of the sterilizer.
    9. Wrap the instruments one by one; if several instruments need to be packed together, make sure they are made of the same material.
    10. Seal the wrapper with special sterilizing tape or use a heat sealer.
    11. Make sure the sterilizing bag is properly placed inside the chamber on top of the trays (resting on the plastic part).
  7. Select the sterilization program.
  8. Start the sterilization cycle. After selecting the sterilization program, place the instruments in the chamber using the trays and the supplied plastic handle. Once the instruments are inside the chamber, close the door by turning the knob. Caution: Ensure the door knob is turned to its maximum position; otherwise, the sterilizer will display an alarm and the program will either not start or will stop during the cycle.
  9. Start the sterilization program. Press the start button, then the sterilizer will begin operating for approximately 30-75 minutes.
  10. Sterilization cycle complete. Once the sterilization cycle is complete, the printer (optional) will automatically print the full cycle report, and the data will be saved to the USB drive (in .txt format). After the pressure drops to zero, you can open the door and remove the instruments. The sterilizer will alert you with an audible signal once the sterilization cycle is finished. Caution: Always use the supplied plastic handle for the tray support when removing instruments.

IMPORTANT: Do not reuse water from the waste tank.

Facility:

  • There must be at least 10 cm of free space around the sterilizer, 25 cm at the top, and enough space for the door to open completely.
  • The area where the sterilizer operates must have adequate ventilation.
  • The sterilizer should be placed on a weight-resistant table at a suitable level for handling.
  • Do not cover or block the side vents or the condenser fan air outlet grille.
  • Do not place the sterilizer near water sources where it may be splashed.
  • Keep it away from other heat sources.

Example report:

================================
Program: WRAPPED
Temperature: 134C
Pressure: 206.0 kPa
Drying time: 08Min
Sterilization time: 4.0 min
--------------------------------
Time Temp. Pressure
Start 12:28:17 089.0C
T1: 12:31:32 087.1C -075.0kPa
T2: 12:33:43 110.2C 052.0kPa
T3: 12:36:37 088.9C -080.0kPa
T4: 12:39:20 114.7C 053.7kPa
T5: 12:43:37 087.9C -080.0kPa
T6: 12:50:40 134.8C 206.0kPa
TS: 134.7C 209.5kPa
Max. Temperature: 135.2C
Min. Temperature: 134.3C
Max. Pressure: 214.0kPa
Min. Pressure: 204.9kPa
T7: 12:54:39 134.4C 211.4kPa
T8: 12:57:36 102.1C -060.0kPa
T9: 12:59:54 098.2C -060.0kPa
End 13:04:07 102.4C
--------------------------------
Cycle No.: 00017
Result: success
Date: 2014-06-07
SN:E54723
Operator:
================================
Manual

Video: