AR2100viewBT is a digital electrocardiograph capable of capturing and simultaneously scan in 12-lead ECG, view real-time integrated LCD screen and print with integrated thermal printer. The device is designed for the control of cardiac functions and / or diagnosis of the patient's health status. Proper use of this device is in a medical environment. You must use qualified personnel and timely made in accordance with the instructions in the User Manual.
AR2100viewBT combines optimized performance for multi-channel ECG equipped with graphic display and printing system 210 mm, with the characteristics of reliability, modularity, versatility and updated that distinguish the latest generation of ECGs.
AR2100viewBT is a portable electrocardiograph mixed power system (mains and rechargeable internal batteries) which in its basic configuration allows:
- Option parameters: automatic ECG parameter measuring (standard)
- PC file option: to archive the examination without PC software for computerized managementof ECG cubeecg;
- Option Real Time PC-ECG: for real-time visualization of the twelve leads on the PC screen and managing both patient clinical record for the filing of the tests in digital format thanks to cubeecg software.
- Record an ECG test automatically, manual and timed;
- Display real-time ECG signal integrated graphic display in format 3, 6, 6 +6 channels;
- ECG signal reproduced on paper of 210 mm, in different formats, thanks to the high-resolution thermal printer;
- Organize examinations through clock, calendar and large alphanumeric keypad to manage user and patient data;
- Store up to 200 records and print additional copies;
- Program up to 4 different profiles of use, able to adapt the operation of the device to different requirements
Thanks to the flexibility of software and the Bluetooth interface, AR2100viewBT may be amended at any time to the needs of each user. The selection among the large number of options available is completely independent and can be performed both at the time of purchase and then without interrupting daily activities.
Within few minutes your AR2100viewBT can have (see optional accessories):
- Option analysis: Automatic ECG analysis programme
- Memory option: Storage of up to 40 complete examinations, with no need to print them out (option "paper saving");
Technical characteristics:
Features | Description |
---|---|
Power supply | Class I |
Internal power | 115-230 V ± 10% 50/60Hz |
Maximum consumption | 0.5 mA a 115 V ~ ±10% |
0.25 mA a 230 V ~ ±10% | |
Network protection | Fusw: T 0.5 A |
Internal energy source | Rechargeable lead battery 12 V - 2Ah |
Applied part | Type CF |
Defibrillation protection | Internal to the device |
Input dynamics | ± 300 mV @ 0 Hz.± 10 mV bandwidth |
Input impedance | > 100 MOhm on each electrode |
Common mode rejection | > 100 dB |
Frequency response | 0.05 - 150 Hz (–3db) with anti-oscilation filter |
Time constant | 3.3 s |
Acquisition | 12 bit |
1000 samples/s/channel printing and filters | |
500 samples/s/channel in calculation and filters | |
Resolution 5 MicroV/bit | |
Leads | 12 standard leads |
Signal memory | 10 seconds each lead in automatic mode |
Recording/display sensitivity | Manual: 5 – 10 – 20 mm/mV |
Automatic: according to number of channels printed | |
Printer system | Thermal printer, 8 dot/mm |
Usable print height | 210 mm |
Print channels | 12 |
Paper transport speed | 5 - 25 – 50 mm/s |
Thermosensitive paper | In rolls: length 30 m, page 210x150 mm with diagram |
Z-fold packets: length 30 m, page 210x150 mm with diagram | |
Pacemaker recognition | Recognizes pulse in accordance with current IEC standards |
Filters | Network interferences: Modified digital notch filter 50 – 60 Hz |
Anti-sway: Digital high-pass filter 0.5 Hz, linear phase | |
Communication interface | Infrared or Bluetooth |
Keyboard | Membrane with functional and alphanumeric extended keyboard |
Display | Monochrome graphic LCD 320x240 pixels, 115x86 mm (5.7 inches) |
Backlit cold cathode fluorescent lamp | |
Analysis programs | Parameter calculation (optional) |
ECG analysis (optional) | |
Arrhythmia program (included) | |
HRV: RR variation (optional) | |
Mode | Continuous |
Operating modes | Manual: acquisition and printing in real time |
Automatic: simultaneous acquisition | |
Pre-programmed: acquisition user defined intervals | |
Arrhythmia: individuation arrhythmic events with continuous recording | |
PC-ECG: real time acquisition with PC visualization | |
HRV: heart rate variability analysis | |
Paper Saving: acquisition without print | |
Autonomy | Internal battery: 1 hour with 6 channels printing |
Recharging | Internal battery: 24 hours 100% |
Protection degree | IP 20 |
Operating environmental conditions | Temperature: +10ºC - +40ºC |
Relative humidity: 25% - 95% (w/o condensation) | |
Atmospheric pressure: 700hPa - 1060 hPa | |
Transport and storage environmental conditions | Temperature: -10ºC - +40ºC |
Relative humidity : 10% - 95% (w/o condensation) | |
Atmospheric pressure: 500 hPa - 1060 hPa | |
Dimensions | 325 x 80 x 345 mm (length x height x depth) |
Weight | 3700 gr w/o paper |
Accordance with the following standards | EN 60601-1: 1990 |
EN 60601-1/A1: 1992 | |
EN 60601-1/A2: 1995 | |
EN 60601-1/A13: 1995 | |
General standards for safety of electrical equipment | |
EN 60601-1-2: 1993 | |
Standards for electromagnetic compatibility of electrical equipment | |
EN 60601-2-25: 1995 | |
EN 60601-2-25/A1: 1999 | |
Special safety standards for electrocardiographs | |
IEC/60601-2-51/Ed.1: 2001 | |
Special safety standards for essential features of recording and analysing single and multichannel electrocardiographs | |
Classification according to regulations 93/42 EEC: class IIa, CE0470 |
Basic equipment:
- Patient cable IEC 10 hoses
- Set of 4 electrodes peripheral type "clip"
- 10 connecting crocodile adaptors 4mm
- 100 Tab electrodes
- Dust cover
- Z-fold paper pack 210mm x 280mm x 200 sheets
- Ruler to count frequencies
- Network cable
- Option Parameter Calculation
- Option ECG File
- Option Real Time PC-ECG
- User manual
Optional (see reference code):
Description | Reference code |
---|---|
Option analysis | 127-9IN2100V |
Option memory | 127-9ME2100V |
Option cubeECG (management software) | 127-109500 |
Specific optional accessories (see reference code):
Description | Reference code |
---|---|
AR2100viewBT User manual (specify language) | 127-199004 |
Optional accessories (see reference code):
Description | Reference code |
---|---|
Set of 4 electrodes IEC peripheral type "clip" Ag / AgCI | 127-160006 |
Set of 4 electrodes pediatric peripheral type "clip" Ag / AgCI | 127-160007 |
Set of 6 precordial electrodes Suction IEC type Ag / AgCI | 127-160001 |
IEC 10 hoses patient cable with 4 mm terminals | 127-131002 |
Universal ECG trolley with shelves and wheels 80 mm | 127-110001 |
Cable support arm for patient universal trolley | 127-110012 |
Infrared Adapter for PC | 127-191007 |
Bluetooth USB key | 127-191001 |
Paper pack 210 x 280 x 200 sheets | 127-121006 |
Electrode gel bottle 260 ml | 127-122002 |
Ruler frequency counter | 127-170003 |
Set of 10 clip-banana adapters | 127-161001 |
Disposable ECG electrodes clip (600 pcs.) | 127-0260017 |
SNAPCLIP Sensitabs adapter | 127-260005 |
Electrodes Tabs (500 pcs.) | 127-0260003 |