Semi-automatic external defibrillator DESA Rescue Sam
Manufacturer Information:
Name or company: Pending update
Email: Pending update
Postal address: Pending update
City: Pending update
Country: Pending update
Responsible person information:
Name or company: Pending update
Email: Pending update
Postal address: Pending update
City: Pending update
Country: Pending update
Warnings and product safety information:
Manufacturer Information:
Name or company: Pending update
Email: Pending update
Postal address: Pending update
City: Pending update
Country: Pending update
Responsible person information:
Name or company: Pending update
Email: Pending update
Postal address: Pending update
City: Pending update
Country: Pending update
Warnings and product safety information:
- RESCUE SAM is a semi-automatic external defibrillator designed for providing simple and direct voice prompts and indications for a straightforward rescue operation.
- It is light-weight and battery powered for maximum portability.
- RESCUE SAM is designed to treat Ventricular Fibrillation (VF) and Fast Ventricular Tachycardia (VT).
Technical specifications:
- OPERATING MODE: semi-automatic
- WAVEFORM: BTE (Biphasic Truncated Exponential type); impedance compensated
- ENERGY: 200 joules (J) fixed as new norms AMA 2010
- Adult: nominal 200 J into a 50 Ω load
- Infant/child: nominal 50 J into a 50 Ω load
- SHOCK ENERGY ACCURACY: According to IEC EN60601-2-4
- SHOCK-TO-SHOCK CYCLE TIME: typically less than 20 seconds
- PROTOCOL: voice prompts and indicators guide user through protocol
- CHARGE CONTROL: automatic by software (arrhythmia detection system and charging control)
- CHARGE TIME FROM “SHOCK ADVISED”: <8 seconds, typical
- VOICE INSTRUCTIONS: detailed voice messages guide responder through use of the defibrillator
- CONTROLS: shock button, info-button, On/Off button
- INDICATORS: LEDs (different colors), info-button
- CHARGE COMPLETE INDICATOR:
- text prompt (press the shock red button)
- flashing red shock button
- DISCHARGE: once charged, the RESCUE SAM discharges if:
- patient’s heart rhythm changes to non-shockable rhythm, or
- the SHOCK button is not pressed within 15 seconds after it is charged, or
- the Power ON/OFF button is pressed to turn OFF, or
- the defibrillator pads are removed from the patient or the pads connector is disconnected.
- SHOCK DELIVERY: shock is delivered if the SHOCK button is pressed while the defibrillator is armed.
- SHOCK DELIVERY VECTOR: via adult defibrillator pads in the anterioranterior (Lead II) position or via reduced-energy pediatric pads in the anterior-posterior position.
- PATIENT ISOLATION: type BF
- BATTERY:12 Volt DC, 4.2 Ah, lithium manganese dioxide, disposable long-life
- BATTERY CAPACITY: min.200 shocks or 4 hours of operating time continuous.
- AUTOMATED AND USER-ACTIVATED SELF-TESTS:
- Daily self-tests: tests internal circuitry, waveform delivery system, battery capacity, and software.
- Battery Insertion test: upon battery insertion, extensive automatic selftests and user-interactive test check device readiness.
- DATA RECORDING AND TRANSMISSION:
- optional:special battery pack for data transmission.
- data stored: first 60 minutes of ECG and the entire incident’s events and analysis decision.
- SIZE: 80x300x270 mm / 0.78x11.8x10.6 in
- WEIGHT: 2.2 kg / 4.8 lb with battery pack installed.
Standard set:
- Main unit
- Carrying case
- Disposable defib pads adult
- Disposable battery pack
- Adult electrodes
Optional accessories:
- 110-RSM003 - Disposable adult pads
- 110-RSM004 - Disposable pediatric pads
- 110-RSM005 - Disposable long-life LiMnO2 battery
- 110-RSM006 - Data management software with USB adapter.
- 110-RSM009 - Disposable preconnected adult pads