Portable pulse oximeter probe NONIN 7500

General product safety

Manufacturer Information:

Name or company: Pending update
Email: Pending update
Postal address: Pending update
City: Pending update
Country: Pending update

Responsible person information:

Name or company: Pending update
Email: Pending update
Postal address: Pending update
City: Pending update
Country: Pending update

Warnings and product safety information:

Open document

Manufacturer Information:

Name or company: Pending update
Email: Pending update
Postal address: Pending update
City: Pending update
Country: Pending update

Responsible person information:

Name or company: Pending update
Email: Pending update
Postal address: Pending update
City: Pending update
Country: Pending update

Warnings and product safety information:

Open document

Pay securely with:
Item reference866-7500FO
Item reference866-7500MONITOR
Portable pulse oximeter probe NONIN 7500
Description

NONIN 7500 Portable probe pulse oximeter
 

References:

  • 866-7500MONITOR - Standard version (includes adult probe clip )
  • 866-7500FO - Version specially designed for MRI environments (it does not include probe, it must be purchased separately. Ref. 866-8000FC20 (6 metres), Ref 866-8000FC30 (9 metres).

 Main characteristics:

  • Lightweight and compact.
  • User friendly. Wide screen and LED allow a clear reading.
  • Resistant design.
  • Over 70 hours of memory available for extended monitoring.
  • Versatile. Monitoring infants to adult patients who are in intensive care or at home.
  • Minimum battery life 16 hours and 4 hours fast recharging.

 MRI (only ref. 866-7500FO):

  • Model 866-7500FO (fiber) is specially designed for MRI environments. The sensor is easily applied using a clamp to hold it firm. The optical fibre sensor avoids radiofrequency burns and artifact detection. It can be used in fixed or outpatient MRI facilities for monitoring infant, pediatric and adult patients.

 Flexible and versatile modes for alarm settings:

  • Patient Safety Mode: Locks alarm limits, volume and time and date settings, prevents unintended changes.
  • Resetting of programmed limits: Resets last settings programmed by user.
  • Limits Settings: Allows user to set the limits and the volume of the alarm according to specific needs.

 Technical specifications:

- Range of oxygen saturation: 0–100% SpO2
- Range of heart rate: 18–321 beats/min
- Indicators:

  • Pulse Quality Indicator: LED bar graph, three color segments.
  • Alarm Indicator: LED, bicolor
  • Alarm Silence Indicator: LED, Amber
  • Numeric displays: 3-digit, 7-segment LED, green
  • Low Charge Indicator: LED, Amber.

Saturation accuracy (Arms)a: 70 - 100%
- Heart rate accuracy: 18–300 beats/min
- Memory: 70 hours (assuming continuous use)
- Working temperature: 0º to +40ºC (30ºF to 104ºF)
Storage /transport temperature: 30ºC to +50ºC (-2ºF to 122ºF)
- Working humidity: 10 - 90% without condensation
- Storage /transport humidity: 10 - 95% without condensation
- Altitude (operating): up to 12,000 m (40,000 feet)
- Hyperbaric pressure: up to 4 atmospheres
- Power supply: 100-240 VAC 50-60 Hz
- Internal power:

  • Battery: 7.2 volt NiMH battery pack
  • Battery (fully charged): minimum 16 hours.
  • Stored battery life: minimum 21 days.
  • Duration of the battery to charge: up to 4 hours.

- Weight: 900 gr (with battery)
- Protection type: Internally battery powered
- Grade of protection: Applied Part TypeBF
- Protection mode: Continuous
- Degree of protection against liquid: IPX2
- Analogue output:

  • SpO2 Range Output: 0-1 VDC (0-100% SpO2), 1.27 VDC (no signal acquisition)
  • Output range of heart rate: 1 VDC (0-300 bpm), 1.27 VDC (no signal acquisition)
  • Event Marker: 0 V (no event), 1 V (event occurred)
  • Accuracy: + - 2% (SpO2), + - 5% (heart rate)
  • Current loaded: 2 mA Maximum

 Optional accessories:

-Optical fibre probe for pulse oximeter NONIN 7500FO:

  • 866-8000FC20 6 metres
  • 866-8000FC30 9 metres

 