Páginas: 1
size="5" For what is used pulseoxymetry? font> < / strong> font> p> other names strong> oxygen saturation, Monitoring oxygenation. definition strong> The pulse oximetry or pulseoxymetry is measured, non-invasive, oxygen carried by the hemoglobin inside the blood vessels. Como funciona strong> The color of blood varies depending on what saturated with oxygen which is due to the optical properties of the heme group of hemoglobin molecule. When the hemoglobin molecule releases oxygen loses its pink color, becoming a tone more bluish leaves and spend less red light. Thus the oximeter determined by measuring oxygen saturation espectrofotométricamente the "degree" of blue blood and blood expresses this "azulez" in terms of saturation. As the light absorption of tissues and blood vein are constant, any change in light absorption between a given time and one post should be exclusively to the arterial blood. The oximeter measured as the ratio, at an interval of time, differences between the absorption of red light and infrared. This relationship is linked directly with the saturation of oxy-hemoglobin. techniques used to conduct strong> It requires an apparatus pulseoxymetry, with a sensor in the form of clip. In the clip is a producer of light that is reflected in the pile of pulpejo finger, this sensor measures the amount of light absorbed by the oxy-hemoglobin circulating in the patient. It should pulpejo massage the patient's finger, then puts the clip with the sensor and is expected to receive information on a screen of the device on which appear the following information: indicators of oxygen saturation Heart rate Curve pulse Limites de la pulseoxymetry strong> Alter of haemoglobin (MetHb or COHP). dyes and pigments in the area of reading (painted nails). external light sources. peripheral hypoperfusion. anemia. Increased venous pulse. Do not detected hiperóxia. Do not detected hypoventilation. indicators strong> In general are useful in patient care which should include an alteration in the oxigenacióno for valuing certain therapeutic: Respiratory Distress in asthma. cyanosis. Poll exercise tolerance. Evaluation control oxygen therapy. Etc. ... use strong> 1. strong> Firstly be obtained information on the proper use of each model, and if necessary adapt needs to know that we have the correct model, because the market there are many models using a wide range of job opportunities through various programmes. 2. strong> Remove paintings nail in the case of using sensors thimble. 3. strong> explain to the patient that is the measurement, stressing the need to move the minimum and not move a finger sensor. 4. strong> Perform measurement away from a light source importantly, pockets, etc.. 5. strong> If carried out continuous measurements for a long time to change, at least every 8 hours, location, to avoid skin lesions. 6. strong> sensors clip should not compress too much, since it could alter the measurement. normal results strong> The oxygen saturation should be greater than 95%. Valores de abnormal results strong> Values increased oxygen saturation: hyperventilation Anxiety Values of diminished oxygen saturation: chronic lung diseases. decompensation or asthma attacks. Heart disease. font> font> p> DIV>
|